CNG dispenser
PRODUCTS CENTER
central africa CNG gas station complete equipment
+86-15601559666
Product Description
6.1 CNG dispenser
Summary
The general type intelligent CNG dispenser uses our company’s independent development high-performance military rank microprocessor control system, which is mainly used to meter CNG filling for CNG vehicle. The industry leading pressure intelligence computing function ensures one-time fully filling and preventing overfill. Scientific CNG filling speed control ensures the reliable control of CNG filling target pressure.
Our independent R&D microcomputer controller uses military rank electronic parts, and passes the harsh environmental suitability, electromagnetic compatibility and safety performance test, which ensures the reliability of microcomputer controller while the CNG dispenser runs under the complex operating environment. We own the proprietary intellectual property rights, there is no obstacle for technology upgrading and rebuilding in future.
Advantages
Industry-leading pressure control Modular design Proprietary intellectual property rights
Key Parameters
CNG Dispenser Series | ||
Basic type | Massflow CNG dispenser | Single-line single-hose,single-line dual-hose,single-line four-hose |
Dual-line single-hose,dual-line dual-hose,dual-line four-hose | ||
Three-line single-hose,three-line dual-hose,three-line four-hose | ||
Technical Parameters | Applicable medium | Compressed Natural Gas(CNG) |
Accurac ymeasuring | ±1.0% | |
Range of flow | (2-30)kg/min(3-40)Nm3/min | |
Rated working pressure | 20MPa | |
Max.working pressure | 25MPa | |
Compressive strength | 37.5MPa | |
Ambient temperature | -40℃-+50℃ | |
Explosive-proof grade | Exdefbmb ⅡAT4Gb | |
Power supply | 220V±15% 50Hz±1Hz | |
Unit of measurement | Kg/Nm³ | |
Minimum scale reading | 0.01 | |
Single counter range | 0~9999.99 | |
Totalize range | 0~99999999.99 | |
Rated power | Single-hose:100W,dual-hose:200W,Four-hose:400W | |
Main Function
Highlight backlight LCD, dual display unit price, CNG volume and sum
Safety protection function for overpressure, overflowing, anti-surge
Ultra-large capacity memory function, 20,000 CNG filling transactions can be saved while off-line, and supports inquiry and print historical data
Refuel by preset volume and sum
Fault self-service diagnostic function, automatic display fault code
Pressure temperature compensation
Breaking protection
Pressure discharge and blow-off
IC card auto settlement and management
Automatic filling pressure control, which assures take out CNG from storage system effectively
Data protection and data delay display when power failure
Display the recent CNG filling data
Monitor malfunction of mass flow meter and stop refueling while mass flow meter has malfunction
Gas leakage and gas lost protection, display alert information
Filter online cleaning function
Manual emergency shut-down valve
Bill printer
6.2 CNG filling/unloading column
Summary
CNG filling/unloading column uses high-performance industrial control microprocessing system, which is the metering equipment used in trade settlement of CNG main station or substation, and mainly filling/unloading & metering for CNG tank car.
Temperature compensation is available as it uses imported mass flow meter with temperature sensor, high accuracy pressure sensor assures the high accuracy metering.
Mass flow meter, manual ball valve, high pressure hose, quick coupling are imported from famous brand abroad.
Designed and manufactured by ourselves, the computer controller uses industrial grade electronic components, and it passed the test of harsh environmental suitability, electromagnetic compatibility and safety, which assures the reliability of computer controller in complex operating environment. With proprietary intellectual property rights, there is no any obstacle in technology upgrading and rebuilding in future.
Runner pipe path isΦ22x4, high pressure hose diameter is 25mm, maximum flow reaches 80kg/min.
Advantages
High accuracy of measuring、High reliability、Proprietary intellectual property rights、 Fast speed for filling
Main function
Safety protection function for overpressure, overflowing
Data protection and data delay display when power failure
Bulk-storage memory function, inquiry shift total volume and total totalizer
Refuel by preset volume and sum
Display the recent CNG filling data
Fault self-service diagnostic function, automatic display fault code
Pressure temperature compensation
Breaking protection
Manual emergency shut-down valve
IC card auto settlement and management (optional)
Bill printer
Data transmission commu
nication interface

Key Parameters
CNGFilling/Unloading Column Series | ||
Basic type | CNG filling column | Single-line single-hose,single-line dual-hose, dual-line single-hose,medium pressure CNG filling column |
CNG unloading column | Single-line single-hose,single-line dual-hose | |
Technical Parameters | Applicable medium | Compressed Natural Gas(CNG) |
Accuracy of measuring | ±1.0% | |
Range of flow | CNG filling column :(3-70)kg/min(3-80)m³/min CNG unloading column :(3-77)kg/min(3-90)m³/min | |
Rated working pressure | 20MPa | |
Max.working pressure | 25MPa | |
Ambient temperature | -40℃-+50℃ | |
Explosive-proof grade | Exdefbmb ⅡAT4Gb | |
Power supply | 220V±15% 50Hz±1HZ | |
Unit of measurement | Kg/Nm³ | |
Minimum scale reading | 0.01 | |
Single counter range | 0~9999.99 | |
Totalize range | 0~99999999.99 | |
Rated power | Single-hose:100W,dual-hose:200W | |
CNG filling station is a specialized fueling facility designed for the safe storage, compression, and dispensing of compressed natural gas (CNG) for vehicles. It is equipped with key systems such as gas compressors, high-pressure storage cylinders, dispensers, and advanced control units to ensure efficient and accurate fueling. The station offers clean energy solutions with lower emissions compared to conventional fuels, supporting environmentally friendly transportation. Built with strict safety standards, it provides reliable operation, leak prevention, and emergency protection systems. Widely used for buses, taxis, and fleet vehicles, it is an essential infrastructure for sustainable fuel supply.